Euroclean UZ 934 Spécifications Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 11
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
8
1 To open
a) Pull the fasterners on the cover outwards.
b) Lift the cover from the container.
2 Dust bag
Fit the opening on the dust bag over the air inlet. Press the
membrane over the flanged edge on the inlet. Secure with
the lock washer. Use only original dust bags.
3 Hose connection
a) Press the hose into the opening until it clicks.
b) Unlock the hose by pressing down on the catch above the
opening.
4 Wand assembly
a) Standard
To connect the wand sections together,
simply insert one section into the other, giving the two
assembled sections a firm push.
b) Telescopic (optional)
Adjust the length of the telescopic wand by pressing its
button and altering the wand length. When vacuuming stairs
it is recommended that the wand is adjusted to its shortest
length.
5 Tools
The accessories shown in the pictures may vary
from model to model.
a) Universal nozzle for both hard floors and carpets
b) Floor nozzle, one way for brush (hard floor) or smooth
for carpet.
c) Crevice Tool designed for cleaning in narrow spaces like
furniture, radiators, corners and joints.
d,e) Combi Brush / Nozzle useful tool for the cleaning of
upholstery, stair carpets, curtains etc.
6 Suction control
The suction control in the hose handle lets you regulate the
air-flow to prevent the nozzles from fastening to the surfaces
you are vacuum cleaning.
7 Start / Stop
8 Filter
The UZ 934 is avaliable in 2 different models,
a standard model and a Hepa model.
a) Cartridge filter: Makes operating without a bag possible.
Check the filter when you empty the container. Change or
clean if it is clogged. Clean the filter by brushing or shaking
it.
b) Hepa filter:Traps 99,99% of all particles larger than 0,3
microns. Hepa-filter should always be installed when picking
up hazardous materials. Never clean the filter if it has been
used for picking-up hazardous materials. Change if it is
clogged.
c) Pre-filter: It is advisable to use the pre-filter and dustbag
together with the Hepa-filter, as they catches the big
particles and extends the lifetime of the Hepa-filter. Pull the
pre-filter over the standard or Hepa-filter. The pre-filter can
be cleaned by washing or shaking it. If washed: let the pre-
filter dry completly before re-installed. Never clean the filter
if it has been used for picking-up hazardous materials.
9 Exhaust filter
a) Lift the grill at the back edge.
b) Pull it outwards.
Replace the used filter and snap the grill back in place
10 Warning
Never attempt to vacuum liquid, glass fragments or ashes!
Wet surfaces can expose the operator to possible electrical
shock.
IMPORTANT!
The UZ 934 is equipped with a specially designed cable,
which if damaged, must be replaced by a cable of the same
type. These cables are availiable at authorized service
shops and must be installed by trained personnel.
The UZ 934 is equipped with a thermal cut-out to protect the
motor and other vital machine parts from overheating.
Should the machine cut out, you will have to wait at least 5-
10 minutes for it to automatically reset. While you are
waiting, switch the machine off and unplug it, then check the
hose, dust bag and filters to be sure that nothing is blocking
the flow of air through the machine.
NB!
Remove the plug from the socket before performing service
or maintenance.
Vue de la page 10
1 2 ... 6 7 8 9 10 11

Commentaires sur ces manuels

Pas de commentaire